Table 1. Certified Values and Uncertainty (℃)
Sample Number |
Testing atmosphere |
Certified value and Uncertainty |
Characteristic Melting Temperature (℃) |
|||
Deformation Temperature (DT) |
Softening Temperature (ST) |
Hemispheric Temperature (HT) |
Flowing Temperature (FT) |
|||
SDRM 040005 579# |
Reducing |
Certified value |
1171 |
1184 |
1192 |
1217 |
Uncertainty |
21 |
30 |
30 |
30 |
||
Oxidizing |
Certified value |
1191 |
1202 |
1215 |
1250 |
|
Uncertainty |
26 |
30 |
33 |
15 |
||
SDRM 040006 580# |
Reducing |
Certified value |
1350 |
1366 |
1373 |
1389 |
Uncertainty |
15 |
15 |
17 |
18 |
||
Oxidizing |
Certified value |
1368 |
1380 |
1387 |
1419 |
|
Uncertainty |
21 |
23 |
24 |
26 |
||
SDRM 040007 581# |
Reducing |
Certified value |
1245 |
1294 |
1314 |
1374 |
Uncertainty |
18 |
15 |
15 |
29 |
||
Oxidizing |
Certified value |
1308 |
1344 |
1369 |
1409 |
|
Uncertainty |
23 |
20 |
17 |
15 |
The reducing atmosphere is obtained by introducing into the furnace the mixture gases of (50±5)% CO2 and (50±5)% H2 (in the most tests) or by sealing in the furnace the proper ratio of graphite and anthracite (in a few tests); the oxidizing atmosphere is obtained with air circulates freely through the furnace.
The certification analyses were performed according to the Chinese National Standard GB/T219-2008 by 8 qualified laboratories.
The homogeneity tests were performed according to GB/T219-2008, the results show that the homogeneity was good.
Expiration of certification: The certification of this CRM is valid until November 1, 2031.
The certified reference material is packed in glass bottles with plastic covers. The net weight is 25g each. It is suggested to keep dryness when stored. The certified reference material should be reduced in size to <0.1mm and ignited at 815℃ for 1 hour before use. This certified reference material is not applicable in the identification of the deviation of furnace temperature, the users should be sure the furnace temperature has been controlled correctly before the testing.
Product detail pictures:
Related Product Guide:
We will devote ourselves to giving our esteemed buyers using the most enthusiastically thoughtful services for Wholesale Primary Reference Material Manufacturer – Reference Material For Steel Testing – Shandong Institute of Metallurgical Science , The product will supply to all over the world, such as: Sweden, Salt Lake City, Bulgaria, Due to our dedication, our products are well known throughout the world and our export volume continuously grows every year. We will continue to strive for excellence by providing high quality products that will exceed the expectation of our customers.
By Doreen from United Arab emirates - 2018.05.15 10:52
Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
By Laura from Czech - 2018.12.25 12:43