Wholesale Knock Crm – Reference Material For Steel Testing – Shandong Institute of Metallurgical Science Detail:
Table 1. Certified Values and Uncertainty (℃)
Sample Number |
Testing atmosphere |
Certified value and Uncertainty |
Characteristic Melting Temperature (℃) |
|||
Deformation Temperature (DT) |
Softening Temperature (ST) |
Hemispheric Temperature (HT) |
Flowing Temperature (FT) |
|||
SDRM 040005 579# |
Reducing |
Certified value |
1171 |
1184 |
1192 |
1217 |
Uncertainty |
21 |
30 |
30 |
30 |
||
Oxidizing |
Certified value |
1191 |
1202 |
1215 |
1250 |
|
Uncertainty |
26 |
30 |
33 |
15 |
||
SDRM 040006 580# |
Reducing |
Certified value |
1350 |
1366 |
1373 |
1389 |
Uncertainty |
15 |
15 |
17 |
18 |
||
Oxidizing |
Certified value |
1368 |
1380 |
1387 |
1419 |
|
Uncertainty |
21 |
23 |
24 |
26 |
||
SDRM 040007 581# |
Reducing |
Certified value |
1245 |
1294 |
1314 |
1374 |
Uncertainty |
18 |
15 |
15 |
29 |
||
Oxidizing |
Certified value |
1308 |
1344 |
1369 |
1409 |
|
Uncertainty |
23 |
20 |
17 |
15 |
The reducing atmosphere is obtained by introducing into the furnace the mixture gases of (50±5)% CO2 and (50±5)% H2 (in the most tests) or by sealing in the furnace the proper ratio of graphite and anthracite (in a few tests); the oxidizing atmosphere is obtained with air circulates freely through the furnace.
The certification analyses were performed according to the Chinese National Standard GB/T219-2008 by 8 qualified laboratories.
The homogeneity tests were performed according to GB/T219-2008, the results show that the homogeneity was good.
Expiration of certification: The certification of this CRM is valid until November 1, 2031.
The certified reference material is packed in glass bottles with plastic covers. The net weight is 25g each. It is suggested to keep dryness when stored. The certified reference material should be reduced in size to <0.1mm and ignited at 815℃ for 1 hour before use. This certified reference material is not applicable in the identification of the deviation of furnace temperature, the users should be sure the furnace temperature has been controlled correctly before the testing.
Product detail pictures:
Related Product Guide:
Our enterprise since its inception, often regards solution excellent as enterprise life, continually strengthen output technology, enhance product high quality and continually strengthen organization total high-quality administration, in strict accordance using the national standard ISO 9001:2000 for Wholesale Knock Crm – Reference Material For Steel Testing – Shandong Institute of Metallurgical Science , The product will supply to all over the world, such as: UAE, Nairobi, Lahore, With the growing of the company, now our products sold and served at more than 15 countries around the world,such as Europe,North America,Middle-east,South America,Southern Asia and so on. As we bear in our mind that innovation is essential to our growth, new product development is constantly.Besides, Our flexible and efficient operation strategies,High quality products and competitive prices are exactly what our customers are looking for. Also a considerable service brings us good credit reputation.