Wholesale Crm Software For Small Business Manufacturers – Coke Series National And Industrial Reference Materials – Shandong Institute of Metallurgical Science
Wholesale Crm Software For Small Business Manufacturers – Coke Series National And Industrial Reference Materials – Shandong Institute of Metallurgical Science Detail:
Table 1. Certified Values for GSB 03-2022-2006 (Mass Fraction %)
Number |
Elements |
TFe |
FeO |
SiO2 |
Al2O3 |
CaO |
MgO |
S |
GSB 03-2022-2006 |
Certified Values |
61.53 |
0.24 |
3.43 |
2.12 |
0.118 |
0.109 |
0.038 |
Uncertainty |
0.10 |
0.01 |
0.04 |
0.05 |
0.007 |
0.005 |
0.002 |
|
Number |
Elements |
P |
Mn |
Ti |
K2O |
Na2O |
Cu |
Ni |
GSB 03-2022-2006 |
Certified Values |
0.068 |
0.276 |
0.052 |
0.026 |
0.034 |
0.0014 |
0.0027 |
Uncertainty |
0.002 |
0.005 |
0.002 |
0.003 |
0.003 |
0.0002 |
0.0003. |
|
Number |
Elements |
Co |
As |
Pb |
Zn |
Cr |
|
|
GSB 03-2022-2006 |
Certified Values |
0.0009 |
0.0011 |
0.0008 |
0.0020 |
0.0054 |
|
|
Uncertainty |
0.0001 |
0.0002 |
0.0001 |
0.0003 |
0.0004 |
|
Table 2. Analysis Methods
Composition |
Method |
TFe |
Titrimetric method after tin (Ⅱ) chloride reduction Titanium (Ⅲ) chloride reduce potassium dichromate titration method |
FeO |
Potassium dichromate titration method Sulfosalicylic acid spectrophotometric method Potentiometric titration method |
SiO2 |
Perchloric acid dehydration gravimetric method The silicomolybdic blue spectrophotometric method ICP-AES |
CaO |
AAS ICP-AES |
MgO |
AAS ICP-AES |
Al2O3 |
EDTA titrimetric method ICP-AES |
Ti |
ICP-AES Diantipyrylmethane spectrophotometric method |
Mn |
ICP-AES AAS Potassium periodate spectrophotometric method |
P |
N-butyl alcohol-chloroform extraction molybdenum blue spectrophotome-tric method The butyl acetate extraction photometric method Phosphovanoclonoiybeate molecular absorption spectromrtric method Bismuth phosphomolybdenum blue photometry ICP-AES |
S |
High frequency combustion infrared absorption method Barium sulfate gravimetric method Combustion iodometric method |
K2O |
ICP-AES AAS |
Na2O |
ICP-AES AAS |
Cu |
ICP-AES AAS GFAAS |
Ni |
AAS GFAAS ICP-AES |
Co |
AAS GFAAS ICP-AES |
As |
Silver diethyldithiocarbamate spectrophotometry Arseno molybdenum blue spectrophotometric method after the extraction separation GFAAS HGAAS ICP-AES |
Pb |
GFAAS AAS ICP-AES ICP-MS |
Zn |
ICP-AES AAS |
Cr |
AAS GFAAS ICP-AES |
The certified reference material is packed in glass bottles with plastic covers. The net weight is 50g each. It is suggested to keep dryness when stored. The certified reference material should be dried at 105℃ for 1 hour before use, then it should be taken out and cooled to room temperature.
Product detail pictures:
Related Product Guide:
We are also focusing on improving the stuff management and QC system so that we could keep great advantage in the fiercely-competitive business for Wholesale Crm Software For Small Business Manufacturers – Coke Series National And Industrial Reference Materials – Shandong Institute of Metallurgical Science , The product will supply to all over the world, such as: Chicago, Ukraine, Singapore, We insist on the principle of "Credit being primary, Customers being the king and Quality being the best", we are looking forward to the mutual cooperation with all friends at home and abroad and we will create a bright future of business.
By Dale from St. Petersburg - 2018.11.22 12:28
The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
By Arabela from Slovak Republic - 2018.09.21 11:44