Table 1. Certified Values for ZBK 306 (Mass Fraction %)
Number |
Elements |
TFe |
FeO |
SiO2 |
Al2O3 |
CaO |
MgO |
ZBK 306 |
Certified Values |
65.66 |
0.54 |
1.92 |
1.64 |
0.056 |
0.102 |
Uncertainty |
0.17 |
0.06 |
0.04 |
0.04 |
0.006 |
0.008 |
|
Number |
Elements |
S |
P |
Mn |
Ti |
K2O |
Na2O |
ZBK 306 |
Certified Values |
0.022 |
0.060 |
0.135 |
0.048 |
0.018 |
0.007 |
Uncertainty |
0.001 |
0.002 |
0.003 |
0.002 |
0.002 |
0.002 |
Table 2. Analysis methods
Composition |
Method |
TFe |
Titanium(III) chloride reduction potassium dichromate titration method |
FeO |
Potassium dichromate titration methodThe potentiometric titrimetric method |
SiO2 |
Perchloric acid dehydration gravimetric methodThe silicomolybdic blue spectrophotometric methodICP-AES |
Al2O3 |
Complexometric titration methodThe chrome azurol S photometric methodICP-AES |
CaO |
ICP-AESAAS |
MgO |
ICP-AESAAS |
S |
Barium sulfate gravimetric methodThe eombustion iodometric method for the determination of sulfur content |
P |
Bismuth phosphomolybdate blue spectrophotometric methodICP-AES |
Mn |
Potassium periodate spectrophotometric methodICP-AESAAS |
Ti |
Diantipyryl methane photometric methodICP-AES |
K2O |
ICP-AES AAS |
Na2O |
ICP-AES AAS |
Expiration of certification: The certification of this CRM is valid until December 1, 2028.
Table 3. Methods for homogeneity testing
Composition |
Analysis methods |
Minimum sample (g) |
TFe |
Titanium(III) chloride reduction potassium dichromate titration method |
0.2 |
FeO |
Potassium dichromate titration method |
0.2 |
SiO2, Al2O3, CaO, MgO |
ICP-AES |
0.1 |
Mn, Ti |
ICP-AES |
0.2 |
P, K2O, Na2O |
ICP-AES |
0.5 |
S |
The eombustion iodometric method for the determination of sulfur content |
0.5 |
The certified reference material is packed in glass bottles with plastic covers. The net weight is 70 g each. It is suggested to keep dryness when stored. The certified reference material should be dried at 105℃ for 1 hour before use, then it should be taken out and cooled to room temperature.
Product detail pictures:
Related Product Guide:
We constantly function like a tangible group to ensure that we can give you the very best high-quality and also the very best cost for Wholesale Chemistry Analyzer Manufacturer – Certified Reference Material – Shandong Institute of Metallurgical Science , The product will supply to all over the world, such as: Latvia, Albania, Paraguay, Now we have a excellent team supplying specialist service, prompt reply, timely delivery, excellent quality and best price to our customers. Satisfaction and good credit to every customer is our priority. We have been sincerely looking forward to cooperate with customers all over the world. We believe we can satisfy with you. We also warmly welcome customers to visit our company and purchase our solutions.
By Lee from Hanover - 2017.08.28 16:02
The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!
By Mary from Gambia - 2018.10.09 19:07