Instrumental Analysis Factory –  Converter Slag Certified Reference Material for Chemical Analysis  – Shandong Institute of Metallurgical Science

products

Instrumental Analysis Factory – Converter Slag Certified Reference Material for Chemical Analysis – Shandong Institute of Metallurgical Science

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We emphasize progress and introduce new merchandise into the market each and every year for Quantitative Chemical Analysis , Certified Reference Material Certificate , Free Crm , Competitive price with high quality and satisfying service make us earned more customers.we wish to work with you and seek common development.
Instrumental Analysis Factory – Converter Slag Certified Reference Material for Chemical Analysis – Shandong Institute of Metallurgical Science Detail:

The CRM is used for the quality control and calibration of analytical instruments in analysis of converter slag. It is also used for the evaluation and verification of accuracy of the analytical methods. The CRM can be used for the transfer of measured value.

Table 1. Certified Values for YSBC 28863-2017 (Mass Fraction %)

Number

Elements

TFe

SiO2

CaO

MgO

Al2O3

FeO*

MnO

TiO2

S

P2O5

 

YSBC 28863-2017

Certified Values

15.33

14.17

44.45

7.01

2.76

11.43

2.40

0.65

0.17

2.21

Uncertainty

0.09

0.09

0.11

0.08

0.04

0.07

0.04

0.02

0.01

0.04

Number

Elements

K2O

Na2O

Cr2O3*

V2O5*

As*

Pb*

Zn*

F*

Cd*

 

 

YSBC 28863-2017

Certified Values

0.10

0.13

0.12

0.186

0.0003

0.0074

0.010

0.39

(0.0001)

 

Uncertainty

0.01

0.01

0.01

0.004

0.0001

0.0004

0.001

0.01

 

Note 1: ( ) Indicates information value

Note 2: * Indicates that it is not within the recommended scope for production proficiency of RMP

Table 2. Analysis methods

Composition

Method

TFe

Titanium(Ⅲ) chloride reduce potassium dichromate titration method

SiO2

Perchloric acid dehydration gravimetric method ICP-AES

CaO

EDTA titrimetric method

Potassium permanganate titration method

 

 

MgO

EDTA titrimetric method

EyDTA titrimetric method ICP-AES

 

Al2O3

EDTA titrimetric method

The chrome azurol S photometric method ICP-AES

FeO

Potassium dichromate titration

 

MnO

ICP-AES AAS

Potassium periodate spectrophotometric method

TiO2

ICP-AES

Diantipyrylmethane spectrophotometric method

 

S

High frequency combustion infrared absorption method Barium sulfate gravimetric method

Combustion iodometric method

ICP-AES

P2O5

Bismuth phosphomolybdenum blue photometry

ICP-AES

K2O

ICP-AES AAS

Na2O

ICP-AES

AAS

 

Cr2O3

ICP-AES AAS

Diphenyl carbazide spectrophotometric method

 

V2O5

ICP-AES

The N-benzoyl’-N-phenylhydroxylamine extraction spectrophotometric method AAS

 

 

As

ICP-AES

Hydride generation ICP-AES AFS

ICP-MS

Hydride generation AAS

 

Pb

ICP-MS ICP-AES

Carrier precipitation- ICP-AES

AAS

Zn

ICP-AES

AAS

F

Ion-selective electrode method Ion chromatography

Cd

ICP-MS

GAAS

Expiration of certification: The certification of this CRM is valid until February 1, 2022.

Table 3. Methods for homogeneity testing

Composition

Analysis methods

Minimum sample (g)

TFe

Titanium(Ⅲ) chloride reduce potassium dichromate titration

0.2

FeO

Potassium dichromate titration

0.2

SiO2

Perchloric acid dehydration gravimetric method

0.2

CaO, MgO

EDTA titrimetric method

0.2

Al2O3, MnO, TiO2, P 2O5, K2O, Na2O, Cr2O3, V2O5, Pb, Zn

ICP-AES

0.1

S

High frequency combustion infrared absorption method

0.1

F

Ion-selective electrode method

0.2

As, Cd

ICP-MS

0.2

The certified reference material is packed in glass bottles with plastic covers. The net weight is 50g each. It is suggested to keep dryness when stored. The certified reference material should be dried at 105℃ for 1 hour before use, then it should be taken out and cooled to room temperature.

Shanghai Baosteel Technology Center

Angang Technology Centre

WISCO Technology Centre

52 Institure of China Industries Group

ChongQing Iron Steel Research Institure Co.Ltd

Standard Sample Institute, Wuhan University of Science and Technology

Shandong Metallurgical Research Institute Test Center

Shandong Metallurgical Product Quality Supervision and Inspection Station


Product detail pictures:

Instrumental Analysis Factory –  Converter Slag Certified Reference Material for Chemical Analysis  – Shandong Institute of Metallurgical Science detail pictures

Instrumental Analysis Factory –  Converter Slag Certified Reference Material for Chemical Analysis  – Shandong Institute of Metallurgical Science detail pictures


Related Product Guide:

Good quality comes initial; company is foremost; small business is cooperation" is our business philosophy which is frequently observed and pursued by our business for Instrumental Analysis Factory – Converter Slag Certified Reference Material for Chemical Analysis – Shandong Institute of Metallurgical Science , The product will supply to all over the world, such as: Lebanon, Bahamas, Rio de Janeiro, we have all day online sales to make sure the pre-sale and after-sale service in time. With all these supports, we can serve every customer with quality product and timely shipping with highly responsibility. Being a young growing company, we might not the best, but we are trying our best to be your good partner.
  • This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
    5 Stars By David Eagleson from Belgium - 2017.01.11 17:15
    The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Emma from Marseille - 2018.06.03 10:17
    Write your message here and send it to us