The corporation keeps to the operation concept "scientific management, superior quality and performance primacy, consumer supreme for 430 Stainless Steel , Sus 304 Stainless Steel , Anthracite Mines , We sincerely look forward to hearing from you. Give us a opportunity to show you our professionalism and enthusiasm. We have been sincerely welcome excellent friends from numerous circles at dwelling and overseas occur to cooperate!
China Crm Sfa Supplier – Reference Material For Physical Testing – Shandong Institute of Metallurgical Science Detail:

Each coal was air dried, reduced in size to <0.2mm, homogenized and packaged into individual bottled units.

Table 1 Certified values and Uncertainty for coal  July-01-2021 to  June -30-2022

GBW No.

Production Batch

Certified Value& Uncertainty

Sulfur

St,d/%

Ash

Ad/%

Volatile Matter

Vd/%

Gross Calorific Value

Qgr,d MJ/kg

Carbon*

Cd /%

Hydrogen*

H d /%

Nitrogen*

Nd /%

True Relative Density (20℃) *

 

Characteristic of Char Residue*(CRC)

Coal Type

GBW11101

L

Certified Value

0.45

10.53

20.17

31.96

79.24

4.22

1.36

1.40

6

Bituminous

Uncertainty

0.03

0.07

0.22

0.16

0.38

0.10

0.04

0.02

GBW11102

c

Certified Value

1.59

9.70

34.48

30.17

73.46

4.65

1.36

1.41

5

Bituminous

Uncertainty

0.03

0.12

0.25

0.16

0.27

0.17

0.05

0.02

GBW11104

m

Certified Value

1.03

17.57

8.07

27.77

74.71

2.26

0.84

1.69

2

Anthracite

Uncertainty

0.02

0.12

0.20

0.11

0.22

0.10

0.04

0.03

GBW11105

j

Certified Value

1.74

16.86

7.86

27.98

74.73

2.37

0.98

1.67

2

Anthracite

Uncertainty

0.03

0.14

0.19

0.15

0.27

0.07

0.03

0.02

GBW11107

g

Certified Value

0.81

9.34

30.53

31.03

76.17

4.58

1.37

1.39

6

Bituminous

Uncertainty

0.02

0.09

0.30

0.15

0.26

0.09

0.02

0.02

GBW11107

i

Certified Value

0.82

9.05

30.54

31.12

76.32

4.54

1.38

1.40

6

Bituminous

Uncertainty

0.03

0.11

0.29

0.17

0.27

0.11

0.03

0.03

GBW11108

t

Certified Value

1.91

13.33

32.97

28.34

69.55

4.39

1.19

1.45

5

Bituminous

Uncertainty

0.03

0.11

0.20

0.16

0.23

0.14

0.05

0.03

GBW11109

s

Certified Value

2.83

31.30

29.21

21.82

53.18

3.66

0.93

1.62

5

Bituminous

Uncertainty

0.05

0.17

0.26

0.22

0.39

0.10

0.03

0.02

GBW11109

u

Certified Value

2.57

30.89

28.26

22.24

54.04

3.72

0.91

1.62

6

Bituminous

Uncertainty

0.06

0.17

0.28

0.22

0.48

0.13

0.03

0.02

GBW11110

q

Certified Value

4.35

28.92

20.47

22.91

56.99

3.23

0.94

1.66

4

Bituminous

Uncertainty

0.06

0.17

0.29

0.16

0.39

0.08

0.03

0.02

GBW11110

r

Certified Value

4.13

33.96

24.35

20.70

51.00

3.25

0.99

1.72

4

Bituminous

Uncertainty

0.07

0.20

0.31

0.19

0.40

0.09

0.04

0.02

GBW11111

u

Certified Value

1.73

15.72

23.54

29.26

72.07

4.14

1.18

1.45

6

Bituminous

Uncertainty

0.05

0.10

0.27

0.14

0.42

0.08

0.04

0.02

GBW11112

L

Certified Value

2.15

22.09

9.55

25.64

68.65

2.30

0.87

1.73

2

Anthracite

Uncertainty

0.06

0.13

0.31

0.15

0.39

0.09

0.04

0.02

GBW11113

L

Certified Value

3.42

16.18

11.99

28.68

72.56

3.28

1.03

1.53

2

Anthracite

Uncertainty

0.05

0.12

0.27

0.15

0.42

0.08

0.04

0.02

GBW11113

m

Certified Value

3.37

16.06

12.10

28.68

72.51

3.31

1.03

1.53

2

Anthracite

Uncertainty

0.06

0.12

0.30

0.17

0.35

0.07

0.04

0.02

GBW11126

g

Certified Value

0.27

9.49

8.14

32.21

83.28

3.16

1.15

1.47

2

Anthracite

Uncertainty

0.02

0.12

0.19

0.10

0.28

0.06

0.04

0.01

Note: * Indicates that it is not within the recommended scope for production proficiency of CNAS

The homogeneity test was done on the bottled units by determination of ash and sulfur. The minimum weight of sample taken for analysis is 1.0g (ash) or 0.05g (sulfur). Variance analysis showed that the variability among different bottles was not significantly different from the variability between replicate determinations.

The validation of the certified values is one year. The certification will be performed for every year once revised certified values can be issued on application by Shandong Institute of Metallurgical Science Co., Ltd.

Characterization of methods using two or more methods of demonstrable accuracy in 9 competent laboratories. 

Item

Analysis method

Total sulfur

GB/T 214-2007 Determination of total sulfur in coal, Eschka method

Ash and Volatile matter

GB/T 212-2008 Proximate analysis of coal

Gross calorific Value

GB/T 213-2008 Determination of calorific value of coal

Carbon and Hydrogen

GB/T 476-2008 Determination of carbon and hydrogen in coal

Nitrogen

GB/T 19927-2008 Determination of nitrogen in coal

True Relative Density

GB/T 217-2008 Determination of true relative density of coal

The certification analyses were performed using the Chinese National Standard (GB) methods by several qualified laboratories.

The certified value was expressed as XT±U, where XT is the mean value and U is the expanded uncertainty (95% confidence level). The uncertainty actually given in table 1 includes allowance for sample degradation within one year.

The statistical analysis and overall direction and coordination of the technical measurements leading to certification were performed by Shandong Institute of Metallurgical Science Co., Ltd.

Before characterization of 9 qualified laboratories, the instruments and equipment used shall be verified or calibrated, and certified reference materials shall be used for monitoring during characterization to ensure the traceability of reference materials.

1) These certified reference materials are packed in a brown glass bottle. Each weights 50g.

2) The bottle containing the materials must be kept tightly stopped and stored in cold and dry place, and opened only when necessary.

3) All data are expressed on dry bases. The moisture (moisture in the general analysis test sample) used for calculating the data on dry bases are determined according to moisture analysis method in GB/T 212-2008 “Proximate Analysis of Coal”.

4) The values given in table 1 of this certificate are those determined on July-01-2021 for CRM.


Product detail pictures:

China Crm Sfa Supplier –  Reference Material For Physical Testing  – Shandong Institute of Metallurgical Science detail pictures

China Crm Sfa Supplier –  Reference Material For Physical Testing  – Shandong Institute of Metallurgical Science detail pictures


Related Product Guide:

Our goal is to satisfy our customers by offering golden service, good price and high quality for China Crm Sfa Supplier – Reference Material For Physical Testing – Shandong Institute of Metallurgical Science , The product will supply to all over the world, such as: USA, Mauritius, Malta, Our expert engineering team will generally be prepared to serve you for consultation and feedback. We're able to also give you with free of charge samples to meet your requirements. Best efforts will likely be produced to provide you the best service and merchandise. When you are keen on our business and items, make sure you speak to us by sending us emails or call us quickly. In an effort to know our merchandise and company extra, you may come to our factory to view it. We'll generally welcome guests from all over the world to our business to create business relations with us. Be sure to feel cost-free to speak to us for small business and we believe we are going to share the best trading experience with all our merchants.
  • The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By Sahid Ruvalcaba from Venezuela - 2018.06.21 17:11
    In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
    5 Stars By Letitia from Ecuador - 2017.04.08 14:55
    Write your message here and send it to us